Brand Name : LLH

Model Number : LPX-40C

Place of Origin : Guangdong Province.China

MOQ : 1 piece

Payment Terms : L/C,D/A,D/P,T/T,Western Union

Supply Ability : 5000-10000 pieces/mouth

Delivery Time : 7-15 days

Packaging Details : box

Price : US $79/Piece

Standards : IEC 61643.11

SPD Type : T2

Maximum Continuous Operating Voltage (Uc) : 385Vac(50Hz)

Maximum Discharge Current (Imax) : 40kA/ 80kA

Response Time : ≤25ns

Contact Now

LPX-40C is a three-phase AC power lightning protection box, specifically designed for three-phase power supply systems to provide comprehensive surge protection against transient overvoltages caused by lightning strikes and power grid fluctuations.

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD
Benefits
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPDIndustrial-Grade Stability: Features optional mode protection and a reliable PCB design for stable, interference-resistant performance in harsh industrial environments.
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPDPrecise Surge Counting: Built-in lightning stroke counter (0.5kA–80kA, 0–999 digits) records surge occurrences for predictive maintenance.
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPDRemote Monitoring: Remote signaling and status indication enable real-time operational monitoring and centralized management.

Applications

Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection devices in three-phase power supply systems.

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD

Product Specification

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD

Standards IEC 61643.11
SPD type T2
Models LPX-40C, LPX-80C
Nominal operating voltage Un 220Vac(50Hz)
Maximum continuous operating voltage Uc 385Vac(50Hz)
Nominal discharge current (8/20μs) In 20kA, 40kA
Maximum discharge current (8/20μs) Imax 40kA, 80kA
Voltage protection level Up ≤1.25kV, ≤1.8kV
Response time tA ≤25ns
Protection Circuit L1,L2,L3-N,N-E
Lightning stroke range 0.9kA(8/20μs)~80kA(8/20μs)
Counting digit 0~999

Mechanical Parameters

Installation method 4 fixed holes, DIN Rail 35mm
Screw torque 5N·m
Strip length 12mm
Wiring cross-sectional area 2.5mm²~10mm²
Product size 178mm×116mm×75mm, 197mm×139mm×90mm
Shell material and surface technology Cold rolled steel plate painted black
Alarm system - Deterioration indication LED green: OK; Off: Fail
Remote signaling contact type Normally closed and normally open switching contacts
Remote signaling contact switching ability 125Vac / 1A, 125Vdc / 0.2A
Maximum connection capacity of remote signaling 2.5mm²
Installation Tips

1.Install the lightning protection box in a dry, well-ventilated indoor environment, and keep it away from flammable materials.

2.Use wires with a cross-sectional area of 2.5mm²~10mm², and tighten the screws to a torque of 5N·m.

3.Ensure reliable earthing, with a ground resistance ≤4Ω, to achieve optimal surge discharge effect.

4.Regularly check the lightning count and status indicator: if the product fails, the indicator will turn off. Replace the faulty device in a timely manner.

5.Do not connect the product to a power supply that exceeds its rated voltage and current.

6.Avoid using the product beyond the specified temperature and humidity ranges.


FAQ
Q1: What is the counting range of the lightning strike counter?
A1: The counter can record lightning strikes with a discharge current ranging from 3kA(8/20μs) to 80kA(8/20μs), with a digital display range of 0 to 999.
Q2: Does the product support remote monitoring?
A2: Yes. It is equipped with normally closed and normally open remote signaling contacts, allowing connection to a monitoring system for remote status tracking.
Q3: What is the difference between LPX-40C and LPX-80C?
A3: The core difference lies in the maximum discharge current (Imax): LPX-40C has an Imax of 40kA, while LPX-80C has an Imax of 80kA, making them suitable for different system protection requirements.
Q4: Can it be installed in outdoor environments?
A4: No. This product is designed for indoor use only. For outdoor applications, please select products with an IP67 protection level.

Product Tags:

AC Whole House Surge Protectors

      

Whole House Surge Protectors 220V

      

Lightning Protection T2 SPD

      
Wholesale Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD from china suppliers

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen LLH Electrical Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0